Low Voltage Power Cables – Copper Conductor
Standard Specification : SNI
COPPER CONDUCTOR (SNI IEC 60502-1 : 2009) – Rated Voltage 0.6/1 kV |
|||||
PVC Sheath | PE Sheath | PVC Sheath | PE Sheath | Cross Section | |
1-5 cores Cables
with PVC covering |
NYY | NY2Y | N2XY | N2X2Y | 1 c: 1.5-800 2-4 c: 1.5-300/400 5 c: 1.5-50 |
+ copper wire screen | NYCY | NYC2Y | N2XCY | N2XC2Y | 1 c: 1.5-800 2-4 c: 1.5-300 5 c: 1.5-50 |
+ copper tape screen | NYSY | NYS2Y | N2XSY | N2XS2Y | |
+ steel round or
aluminium wire armor |
NYRGbY | NYR2Y | N2XRY | N2XR2Y | 1 c: 10/25-800
2-4 c: 1.5-300 |
+ steel flat wire armor | NYFGbY | NYFGb2Y | N2XFGbY | N2XFGb2Y | 2-4 c: 1.5-300 5 c: 1.5-50 |
+ double steel or
aluminium tape armor |
NYBY NYB(AL)Y |
NYB2Y | N2XBY | N2XB2Y | 1 c: 16-800
2-4 c: 1.5-300 |
COPPER CONDUCTOR ( SNI 04-6629.3 : 2006 ) – Rated Voltage 450/750 V |
|||
PVC Insulation | Cross Section | ||
Single core Cable | NYA | 1 c: 1.5-400 |
COPPER CONDUCTOR ( SNI 04-6629.4 : 2006 ) – Rated Voltage 0.6/1 kV |
||
PVC Insulation | Cross Section | |
1-5 cores Cables
with PVC covering |
||
NYM | 2-5 c: 1.5-35 |
Standard Specification : IEC
COPPER CONDUCTOR (IEC 502) – Rated Voltage 0.6/1 kV |
|||||
PVC Insulation | XLPE Insulation | Cross Section | |||
Single core Cable | NYA (450/750 V) ( IEC 227 – 1) | N2XA | 1 c: 1.5-400 | ||
Twisted Aerial Cable | NF2X | 2 c: 10-16 4 c: 10-35 |
|||
+ steel messenger | NF2X-T | 2-3 c: 25-95 | |||
PVC Sheath | PE Sheath | PVC Sheath | PE Sheath | ||
2 cores flat cable | F-VVF | 2 c: 1.5-16 | |||
1-5 cores Cables
with PVC covering |
NYY | NY2Y | N2XY | N2X2Y | 1 c: 1.5-800 2-4 c: 1.5-300/400 5 c: 1.5-50 |
NYM ( IEC 227 – 4 ) | 2-5 c: 1.5-35 | ||||
+ copper wire screen | NYCY | NYC2Y | N2XCY | N2XC2Y | 1 c: 1.5-800 2-4 c: 1.5-300 5 c: 1.5-50 |
+ copper tape screen | NYSY | NYS2Y | N2XSY | N2XS2Y | |
+ steel round or
aluminium wire armor |
NYRY | NYR2Y | N2XRY | N2XR2Y | 1 c: 10/25-800
2-4 c: 1.5-300 |
+ steel flat wire armor | NYFGbY | NYFGb2Y | N2XFGbY | N2XFGb2Y | 2-4 c: 1.5-300 5 c: 1.5-50 |
+ double steel or
aluminium tape armor |
NYBY | NYB2Y | N2XBY | N2XB2Y | 1 c: 16-800
2-4 c: 1.5-300 |
+ lead sheath | NYKY | NYK2Y | N2XKY | N2XK2Y | |
+ lead sheath + double steel or aluminium tape armor |
NYKBY | NYKB2Y | N2XKBY | N2XKB2Y | |
+ lead sheath + steel round or aluminium wire armor |
NYKRY | NYKR2Y | N2XKRY | N2XKR2Y | 1 c: 16-800
2-4 c: 1.5-300 |
+ lead sheath + steel flat wire armor |
NYKFGbY | NYKFGb2Y | N2XKFGbY | N2XKFGb2Y | 2-4 c: 1.5-300
5 c: 1.5-50 |